User Manual

Table Of Contents
Document Name: Common Commands and Attributes v1.3.0 Revision: 1.2
configures the door alarm to be an environmental alarm.
SET ACL PW1 EQ
configures the PW1 alarm source to be an alarm related to equipment failure.
GET ACL PDL
Reply:
QS
means that PDL alarm affects quality of service on the equipment.
Note! Axell Wireless equipment is always delivered with recommended alarm
configurations, why reconfiguring the alarm class should only be performed under
special circumstances, except for the EX1-EX4 alarms, which are implementation
specific.
7.2 AC1 – Compressed Alarm Severity and Alarm Class
Configurations
7.2.1 Overview
A compact message retrieving alarm severity and alarm class for a number of alarm
sources.
7.2.2 Usage
Attribute type: Read only
This is a compact message to retrieve Severity and Class of the different alarm
sources EX1, EX2, EX3, EX4, DOO, VLI, LGO, CLR, FWU, FWF, UAD, UDE, UPM,
UDM, UPW and RXQ.
Format:
<SevEX1> <ClassEX1> <SevEX2> <ClassEX2> .. <SevRXQ> <ClassRXQ>
Example:
GET AC1
Replies:
CR EN CR EN CR EN CR EN WA EN WA EN WA EN MI EN WA PR WA PR WA PR WA PR WA PR WA EN
which are the severities and classes for the alarm sources EX1..RXQ.
Note! The alarm severities and alarm classes can also be read and set with
commands
GET/SET ASE
and
GET/SET ACL
7.3 AL1 - Compressed Alarm Format
7.3.1 Overview
A compact message retrieving alarm configurations for EX1, EX2, EX3, EX4 and
Common Commands and Attributes 23/123