User Manual

Table Of Contents
Document Name: Common Commands and Attributes v1.3.0 Revision: 1.2
6.9.2 Usage
Reply format:
X
X=0 means status is OK
X=1 means status is ERROR
X=- (dash) means status is indeterminable, or alarm source is not measured.
Example:
GET EX3
Replies:
0
meaning status is OK.
6.10 EX4 – displays status of external alarm input 4
6.10.1 Overview
This read-only attribute displays the status of the external alarm input 4.
6.10.2 Usage
Reply format:
X
X=0 means status is OK
X=1 means status is ERROR
X=- (dash) means status is indeterminable, or alarm source is not measured.
Example:
GET EX4
Replies:
0
meaning status is OK.
6.11 EXT – External alarm pin configuration
6.11.1 Overview
This read and write-attribute configures if absence or presence of signal should
cause an alarm on the external alarm inputs.
6.11.2 Usage
This read and write attribute configures the polarity of the external alarm inputs.
Format:
X Y Z W
X is configuration for alarm pin 1
Y is configuration for alarm pin 2
Common Commands and Attributes 21/123