6.2 DOO – displays status of the door alarm source
6.2.1 Overview
This read-only attribute displays the status of the door, and is read from the alarmd
shared memory.
6.2.2 Usage
Reply format:
X
X=0 means status is OK
X=1 means status is ERROR
X=- (dash) means status is indeterminable, or alarm source is not measured.
Example:
GET DOO
Replies:
0
meaning status is OK.
6.3 DST – displays status of the door
6.3.1 Overview
This read-only attribute displays the current status of the door, and can be used to
speed up testing of the repeater or to show actual door status in the RMC as
opened or closed, regardless of if door status is in error.
6.3.2 Usage
Format:
X
where
X is actual door status.
Reply = 0 means door is closed, while 1 means door is open.
Example:
GET DST
Reply:
1
means door is currently open.
6.4 EAC – External alarm configuration
6.4.1 Overview
This read and write attribute displays and configures usage of the external alarm
Common Commands and Attributes 17/123