User's Manual
Axell BSF3604-490-510-DP-AC (61-103001) Repeater
Product Description and User’s Manual
© Axell Wireless Ltd Doc. No. 61-103001HBK Issue 3 29
4.5 Fiber Optic Connection
Class 1 Laser
This product is equipped with class 1 lasers, as per definition in EN 60825-1.
Un-terminated optical receptacles may emit laser radiation. Do not stare into
the beam or view with optical instruments
Use the following over the complete fiber link between the OMU and the Repeater:
Single-mode type fiber 9/125
Use SC/APC connectors (8 degree angle) for all connections
Connecting the Fiber Optic Cable
1. The fiber optic cable with its SC/APC connector must be passed through the cable gland on
the side of the repeater. If the rubber sealing insert is already inside the gland it must first be
removed.
2. Ensure that there is enough cable slack between the cable gland and the fiber optic converter
module to connect the free SC/APC connector to the SC/APC receptacle on the F/O
converter module.
Make sure the fiber optical cable is not bent too sharply inside the repeater as
this can damage the cable and lead to communication disruptions.