User's Manual
Axell BSF3604-450-470-DP-AC (61-101001) Repeater
Product Description and User’s Manual
© Axell Wireless Ltd Doc. No. 61-101001HBK Issue 1 33
4.7.2.1 Backup Battery
● A rechargeable battery pack is mounted in a small recess on the PSU module. The PSU
module also includes charging and supervision electronics.
● The backup battery will provide the Control Module and modem with enough capacity to
send an alarm in case of input power failure.
● The battery can be switched on and off. The switch is placed adjacent to the main power
on/standby switch on the PSU module.
● At delivery the back-up battery is connected.
● The battery is replaced by removing the restraining clip and lifting the battery pack out of
the recess and disconnecting the cable.
Figure 4-13: Backup Battery
4.7.2.2 Connecting the Power Source
● The BSF unit is supplied with an AC Mains cable with a free socket which mates with the
panel plug on the side of the unit.
● Power Source: 115 VAC 60 Hz
● The power supply module has a switch which allows it to be set in “on” position or in
“stand by”.
NOTE: With the PSU module on/standby switch in the standby position the repeater is still
connected to the AC power supply but is not operational.
● To disconnect the repeater completely from the AC supply the PSU on/standby switch
should be set in the standby position and the mains flying socket removed from the panel
plug on the side of the repeater.
Connector