User's Manual

Axell BSF3604-450-470-DP-AC (61-101001) Repeater
Product Description and User’s Manual
© Axell Wireless Ltd Doc. No. 61-101001HBK Issue 1 23
468.2mm
559.3mm
234.1mm 234.1mm
Hole to take
M8 Rawlbolt
Hole to take
M8 Rawlbolt
Hole to take
M8 Rawlbolt
Hole to take
M8 Rawlbolt
Center line of BSF
100
mm
8
mm dia
.
Bolt head
Washer
Sleeve/Anchor
BSF-3604 should be fixed to a solid wall (these include brickwork, blockwork, and concrete.), due
to the weight of the cell enhancer, fixing to a hollow wall is not recommended.
Always check that there are no pipes or cables hidden in the wall beneath the area to be drilled.
Various pipe and cable detectors are available to check this.
To provide secure fixing to a solid wall, the
most common method is drilling and plugging.
The size of fixing is dependent on the item to
be fixed and the nature of the wall, Repeater
50-122503 should be fixed with mild steel, M8
x 100mm rawl bolts or similar.
Right: M8 rawl bolt of the type recommended
to fix BSF-3604 to a wall.
First mark out on the chosen wall the fixing centers of the BSF
Figure 4-2: Fixing Centers