User Manual

Axell Wireless Limited
Technical Literature
Dual Band Fiber Fed BDA 60-232301
Document Number
60
-
232301HBK
Issue No.
2
Date
/
12
/
2009
Page
35
3.1. 60-232301 Specification
PARAMETER SPECIFICATION
Optical Downlink
Optical Input Alarm Threshold
< -9dBm at 1310nm
RF Downlink
Passband
Frequency
UHF
380
-
385 MHz
800MHz
851-869 MHz
Passband Gain
50dB
Passband Ripple
1.5 dB
Switch Attenuator
0dB to 15dB (± 1dB) in 1dB steps
1dB Compression
UHF
+38dBm
800MHz
+45dBm
OIP3
UHF
+50d
Bm
800MHz
+63dBm
ALC setting
2dB below compression
In Band Spurious Noise (30kHz B/W)
< -13dBm @ (Max gain)
RF Uplink
Passband
Frequency
UHF
390-395 MHz
800MHz
806-824 MHz
Passband Gain
>50 dB
Passband Ripple
1.5 dB
Switch Attenuator
0dB to 30dB (± 1dB) in 2dB steps
1dB Compression
+30dB
ALC Setting
0dBm (FCC -13dBm 3 Carriers)
OIP3
+40dBm
Noise Figure
<5dB (max. gain)
In Band Spurious Noise
(
30kHz B
/W)
<
-
13dBm @ (Max gain)
Optical Uplink
F/O TX Output Power
> 0dBm at 1550nm
General
Case Size
909mm x 780mm x 275mm
Case Material
Aluminium Alloy (2mm)
Case Finish
Light Grey RAL7035 Semi-gloss
AC Supply Voltage
110V to 240V
RF Connectors
N type female
Optical Connectors
SC/APC
Alarms Fitted
UHF Downlink
UHF Uplink
800MHz Downlink
800MHz Uplink
F/O RX
F/O TX
Temperature
Range
operation
-20°C to +60°C
storage
-40°C to +70°C
Humidity
95% RHNC