4.2.4.13. 12V Relay Board (20-001601)
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is
equipped with two dual pole change-over relays with completely isolated wiring, accessed via screw
terminals. Both relays are provided with polarity protection diodes and diodes for suppressing the
transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on
neighbouring circuits. Its common use is to amalgamate all the alarm signals into one, volts-free relay
contact pair for the main alarm system.
20-001601 Specification
PARAMETER SPECIFICATION
Operating voltage 8 to 30V (floating earth)
Alarm threshold Vcc - 1.20 volt +15%
Alarm output relay contacts:
Max. switch current 1.0Amp
Max. switch volts 120Vdc/60VA
Max. switch power 24W/60VA
Min. switch load 10.0µA/10.0mV
Relay isolation 1.5kV
Mechanical life
>2x10
7
operations
Relay approval BT type 56
Connector details Screw terminals
operational -10°C to +60°C Temperature
range
storage -20°C to +70°C
4.2.4.14. 24V Relay Board (20-001602)
The General Purpose 24V Relay Board (20-001602) allows the inversion of signals and the isolation
of circuits. It is equipped with two dual pole change-over relays RL1 and RL2, with completely isolated
wiring, accessed via screw terminals. Both relays are provided with polarity protection diodes and
diodes for suppressing the transients caused by "flywheel effect" which can destroy switching
transistors or induce spikes on neighbouring circuits. Its common use is to amalgamate all the alarm
signals into one, volts-free relay contact pair for the main alarm system.
20-001602 Specification
PARAMETER SPECIFICATION
Operating voltage 8 to 30V (floating earth)
Alarm Threshold Vcc - 1.20 volt +15%
Alarm output relay contacts:
Max. switch current 1.0Amp
Max. switch volts 120Vdc/60VA
Max. switch power 24W/60VA
Min. switch load 10.0µA/10.0mV
Relay isolation 1.5kV
Mechanical life >2x107 operations
Relay approval BT type 56
Connector details Screw terminals
operational -10°C to +60°C Temperature
range
storage -20°C to +70°C