3.2 FO BDA Electrical Specifications
PARAMETER SPECIFICATION
217.5-218.0MHz (Tx)
Frequency range:
219.5-220.0MHz (Rx)
Bandwidth: 0.5MHz
Gain: 0dB
Uplink Gain Adjustment: 0 - 30dB (in 2dB steps)
Downlink gain adjustment: 0-15dB (in 1dB steps)
Uplink Power: 1W
Downlink Power: 40W (20W x2)
IP3: Uplink 47dBm
IP3: Downlink 54dBm
Noise Figure: <6dB
VSWR: better than 1.3:1
RF Connectors: N type, female
F/O Connectors: FC/APC
operational:
-10°C to +55°C
Temperature range:
storage:
-40°C to +70°C
1 PSU
2 FO Modules
Alarms Fitted:
(volt-free contacts/TTL)
3 Amplifiers