Handbook
Table Of Contents
- AMENDMENT LIST RECORD SHEET
- INTRODUCTION
- 1.SAFETY CONSIDERATIONS
- 2.OVERVIEW/SYSTEM DESCRIPTION
- 3.SPECIFICATIONS
- 4.SYSTEM DRAWINGS
- 5.SUB-UNIT MODULES
- 5.1Bandpass Filter (02-011601)
- 5.22-Way Splitter/Combiner (05-002602)
- 5.34-Way Splitter/Combiner (05-003302)
- 5.4¼Watt 0- -30dB Switched Attenuator \(10-0007
- 5.5Low Noise Amplifiers (11-005902 & 11-006702)
- 5.5.1Description
- 5.5.2Technical Specification (11-005902)
- 5.5.3Drg. No. 11-005902 LNA General Assembly Drawing
- 5.5.4Drg. No. 11-005970, LNA Circuit Diagram (RF)
- 5.5.5Drg. No. 11-005971, LNA Circuit Diagram (DC Wiring Layout)
- 5.5.6Technical Specification (11-006702)
- 5.5.7Drg. No. 11-006702, LNA General Assembly Drawing
- 5.5.8Drg. No. 11-006770, LNA Circuit Diagram (RF Components)
- 5.5.9Drg. No. 11-006771, LNA DC Wiring Diagram
- 5.610Watt Power Amplifier (12-002105)
- 5.73 Stage Alarm Board (12-002201)
- 5.8DC/DC Converter, 24V in, 12V 8A out (13-003011)
- 5.9Channel Control & Channel Selective Modules (17-002101 & 17-009127)
- 5.1024V Single Relay Board (80-008902)
- 5.1124V 400W Flat-Pack Power Supply (96-300011)
- 6.INSTALLATION
- 7.MAINTENANCE
- APPENDIX AINITIAL EQUIPMENT SET-UP CALCULATIONS
800MHz BDA (Pasadena Figuero Tunnel)
Maintenance Handbook
H/book Number:-60-056100HBKM
Issue No:-1
Date:-21/10/2003
Page:-
9 of 52
1.3 Chemical Hazard
Beryllium Oxide, also known as Beryllium Monoxide, or Thermalox™, is sometimes used
in devices within equipment produced by Aerial Facilities Ltd. Beryllium oxide dust can be
toxic if inhaled, leading to chronic respiratory problems. It is harmless if ingested or by
contact.
Products that contain beryllium are load terminations (dummy loads) and some power
amplifiers. These products can be identified by a yellow and black “skull and crossbones”
danger symbol (shown above). They are marked as hazardous in line with international
regulations, but pose no threat under normal circumstances. Only if a component containing
beryllium oxide has suffered catastrophic failure, or exploded, will there be any danger of the
formation of dust. Any dust that has been created will be contained within the equipment
module as long as the module remains sealed. For this reason, any module carrying the
yellow and black danger sign should not be opened. If the equipment is suspected of failure,
or is at the end of its life-cycle, it must be returned to Aerial Facilities Ltd for disposal.
To return such equipment, please contact the Quality Department, who will give you a
Returned Materials Authorisation (RMA) number. Please quote this number on the packing
documents, and on all correspondence relating to the shipment.
PolyTetraFluoroEthylene, (P.T.F.E.) and P.T.F.E. Composite Materials
Many modules/components in AFL equipment contain P.T.F.E. as part of the RF insulation
barrier.
This material should never be heated to the point where smoke or fumes are evolved. Any
person feeling drowsy after coming into contact with P.T.F.E. especially dust or fumes
should seek medical attention.
1.4 Emergency Contact Numbers
The AFL Quality Department can be contacted on:
Telephone +44 (0)1494 777000
Fax +44 (0)1494 777002
e-mail qa@aerial.co.uk