Handbook
Table Of Contents
- AMENDMENT LIST RECORD SHEET
- INTRODUCTION
- 1.SAFETY CONSIDERATIONS
- 2.OVERVIEW/SYSTEM DESCRIPTION
- 3.SPECIFICATIONS
- 4.SYSTEM DRAWINGS
- 5.SUB-UNIT MODULES
- 5.1Bandpass Filter (02-011601)
- 5.22-Way Splitter/Combiner (05-002602)
- 5.34-Way Splitter/Combiner (05-003302)
- 5.4¼Watt 0- -30dB Switched Attenuator \(10-0007
- 5.5Low Noise Amplifiers (11-005902 & 11-006702)
- 5.5.1Description
- 5.5.2Technical Specification (11-005902)
- 5.5.3Drg. No. 11-005902 LNA General Assembly Drawing
- 5.5.4Drg. No. 11-005970, LNA Circuit Diagram (RF)
- 5.5.5Drg. No. 11-005971, LNA Circuit Diagram (DC Wiring Layout)
- 5.5.6Technical Specification (11-006702)
- 5.5.7Drg. No. 11-006702, LNA General Assembly Drawing
- 5.5.8Drg. No. 11-006770, LNA Circuit Diagram (RF Components)
- 5.5.9Drg. No. 11-006771, LNA DC Wiring Diagram
- 5.610Watt Power Amplifier (12-002105)
- 5.73 Stage Alarm Board (12-002201)
- 5.8DC/DC Converter, 24V in, 12V 8A out (13-003011)
- 5.9Channel Control & Channel Selective Modules (17-002101 & 17-009127)
- 5.1024V Single Relay Board (80-008902)
- 5.1124V 400W Flat-Pack Power Supply (96-300011)
- 6.INSTALLATION
- 7.MAINTENANCE
- APPENDIX AINITIAL EQUIPMENT SET-UP CALCULATIONS
800MHz BDA (Pasadena Figuero Tunnel)
Maintenance Handbook
H/book Number:-60-056100HBKM
Issue No:-1
Date:-21/10/2003
Page:-
21 of 52
5.5.3 Drg. Nō. 11-005902 LNA General Assembly Drawing
BYDAT EDES CRIPT IO NNo
ISSUE
1 23 456 78 9
A
B
C
D
E
F
1
2
3
4
5
6
7
8
9
F
E
D
A
B
C
Fax : 01494 777002
Tel : 01494 777000
Aerial Facilities Ltd
TWO DECIMAL PLACES ± 0 .1mm
ONE DECIMAL PL ACE ± 0 .3 mm
NO DECIMAL PL ACE ± 1 mm
BY AERIAL F ACIL IT IES L TD.
PERMISSIBLE ONLY IF EXPRESSL Y AUTHORISED IN WRITING
REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS
THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD.
DRAWN
CHKD
AL L DIM ENSIO NS ARE IN mm
UNL ESS O THERWISE STAT ED
APPD
DAT E
TO L ERANCES
SCALE
England
CUSTO MER DRG .No
TITLE
A
3
900MHz LOW NOISE AMPLIFIER
WITH RELAY ASSEMBLY DRAWING
11-005902
AA
1.5:1
MNR 25/03/02
PRE-PRODUCTION ISSUE
25/03/02
MNR
R53
+
J5
R5 9
C5
RL1
R58
CO N1
Limited
Aerial Fa cilities
VOUT
R55
R54
D3
VR1
IC4
R41
R42
k
C19
C16
J4
J2 J1
C10
C6
+
+
C4
REG 3
VIN
ABC
R39
+
ZD 3
C14
+
IC3
R38
R4 0
+
C17
+
+
C15
C8
R52
C13
IC2
C7
C
1
1
+
+
C9 R47
R5 0
J3
+
C12
R5 1
R48
R4 4R4 3
REG1
R46
COMPONENTS TO BE ADDED TO 11-003912,ITEM 15,DC PCB SUB-ASSEMBLY
5
21
2
22
2
4 24
2
IN 2 PLACES
25
4
3
327
17 24
2
8 26 30 27
2
20
2
1533
2
27
5
16 23
5
1
6
IN 2 PLACES
2 25
10
DC PCB
RF PCB
R4 9
11-005925 ISS.1
R2
R4
C2
L2
L4
C1 0
TR2
L6
R6
R1 2
R1 1
C4
R5
C1
R3
R1
L5
R1 0
R1 5
CPL 2
R1 3
R1 4
COMPONENTS TO BE ADDED TO 11-005911,ITEM 16,RF PCB SUB-ASSEMBLY
2. LIDS,ITEMS 2 & 3 AND LABELS,
1. SOLDER JOINTS TO BE MADE USING OR
2819
34
see note 2
LABEL DETAILS - SCALE 1:1
35
see note 2
see note 2
31
IN 4 PLACES
ITEMS 31,34 & 35,TO BE FITTED ON TEST
AFL
********
11-005902
800-1000MHz
20dB 12-24vDC
**/**/20**
Limited
Aerial Facilities
IN
REF.
FREQ.
GAIN
S/N
DATE
0086
OUT
AFL
SENSITIVE
DEVICES
E L E C TR O S TA TI C
OBSERVE PRECAUTIONS
ATTENTION
FOR HANDLING
AFL
PRODUCTION ISSUE(ECN2539)
MNR
08/04/02
1A
AC
IB