Handbook
Table Of Contents
- AMENDMENT LIST RECORD SHEET
- INTRODUCTION
- 1.SAFETY CONSIDERATIONS
- 2.OVERVIEW/SYSTEM DESCRIPTION
- 3.SPECIFICATIONS
- 4.SYSTEM DRAWINGS
- 5.SUB-UNIT MODULES
- 5.1Bandpass Filter (02-011601)
- 5.22-Way Splitter/Combiner (05-002602)
- 5.34-Way Splitter/Combiner (05-003302)
- 5.4¼Watt 0- -30dB Switched Attenuator \(10-0007
- 5.5Low Noise Amplifiers (11-005902 & 11-006702)
- 5.5.1Description
- 5.5.2Technical Specification (11-005902)
- 5.5.3Drg. No. 11-005902 LNA General Assembly Drawing
- 5.5.4Drg. No. 11-005970, LNA Circuit Diagram (RF)
- 5.5.5Drg. No. 11-005971, LNA Circuit Diagram (DC Wiring Layout)
- 5.5.6Technical Specification (11-006702)
- 5.5.7Drg. No. 11-006702, LNA General Assembly Drawing
- 5.5.8Drg. No. 11-006770, LNA Circuit Diagram (RF Components)
- 5.5.9Drg. No. 11-006771, LNA DC Wiring Diagram
- 5.610Watt Power Amplifier (12-002105)
- 5.73 Stage Alarm Board (12-002201)
- 5.8DC/DC Converter, 24V in, 12V 8A out (13-003011)
- 5.9Channel Control & Channel Selective Modules (17-002101 & 17-009127)
- 5.1024V Single Relay Board (80-008902)
- 5.1124V 400W Flat-Pack Power Supply (96-300011)
- 6.INSTALLATION
- 7.MAINTENANCE
- APPENDIX AINITIAL EQUIPMENT SET-UP CALCULATIONS
800MHz BDA (Pasadena Figuero Tunnel)
Maintenance Handbook
H/book Number:-60-056100HBKM
Issue No:-1
Date:-21/10/2003
Page:-
15 of 52
4. SYSTEM DRAWINGS
4.1 Drg. Nō. 60-056194, 800MHz BDA Case Outline Drawing
250 [9.9"]
LOCKABLE
DOOR
CATCH
volt age
High
DANGER
H eav y
CAUTION
700 [2'-3.6"]
CE- / - N
P roduct r ef :
B P A 800MH z
Aerial Facilities
Li m i t ed
BYDAT EDESCRIPT IO NNo
ISSUE
12
3
4
5
6
7
89
A
B
C
D
E
F
1 23456789
A
B
C
D
E
F
Fax : 01494 777002
Fax : 01494 777000
Aerial Facilities Limited
THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES L TD.
REPRO DUCTION O R USE O F THIS DESIG N BY O T HERS IS
PERMISSIBL E O NLY IF EXPRESSL Y AUT HO RISED IN WRITING
BY AERIAL FACILITIES LTD.
NO DECIM AL PL ACE ± 1 mm
O NE DECIM AL PL ACE ± 0 .3 mm
TWO DECIMAL PL ACES ± 0 .1 mm
AL L DIMENSIONS ARE IN mm
UNLESS OTHERWISE STATED
CHKD
DRAWN
APPD
DAT E
TOLERANCES
SCALE
England
CUSTO MER DRAWING .No
TITLE
3
A
PASADENA BLUE LINE. LOCATION 2.
BDA 800MHz. 8 CHANNEL OUTLINE DRAWING
60-056194
1A
1:8
MNR
01/07/03
P RODUCTI ON ISS UE
01/07/03
MNR
620 [2'-0.4"]
909 [2'-11.8"]
M6 EARTH STUD
115V AC INPUT
MATERIAL: MILD STEEL
FINISH: PAINTED TO RAL 9017
WALL FIXINGS: M8 (5/16")
RF CONNECTORS: N TYPE FEMALE
ENVIRONMENTAL CLASS.: IP65
SEMI-GLOSS TRAFFIC BLACK
667 [2'-2.3"]
700 [2'-3.6"]
PSU ALARM
TO ANTENNA
CONNECTION TO BDA
ALARMS
820 [2'-8.3"]
PB GD