Handbook
Table Of Contents
- AMENDMENT LIST RECORD SHEET
- INTRODUCTION
- 1.SAFETY CONSIDERATIONS
- 2.OVERVIEW/SYSTEM DESCRIPTION
- 3.SPECIFICATIONS
- 3.1Parts Lists
- 3.2Technical Specifications
- 3.2.1UHF ONE to Tunnels 1 & 2 Technical Specification
- 3.2.2UHF1A Technical Specification
- 3.2.3UHF ONE to Location TWO Technical Specification
- 3.2.4UHF TWO to Tunnels 1 & 2 Technical Specification
- 3.2.5UHF TWO to Location TWO Technical Specification
- 3.2.6800MHz Bi-directional Amplifier to Location TWO Technical Specification
- 3.3Mechanical Specification (UHF1/1A & UHF2 Wall Cases)
- 4.SYSTEM DRAWINGS
- 5.SUB-UNIT MODULES
- 5.1UHF 1 Air Interface (60-055901)
- 5.1.1Bandpass Duplexers (02-013401)
- 5.1.22 & 4 Way UHF Splitters (05-002603 & 05-003401)
- 5.1.3¼Watt 0- -30dB Switched Attenuator \(10-00
- 5.1.4Low Noise Amplifiers (11-006102, 11-007302 & 11-007402)
- 5.1.4.1General Description
- 5.1.4.2Technical Specification (11-006102)
- 5.1.4.3Drg. No. 11-006102, Low Noise Amplifier General Assembly
- 5.1.4.4Drg. No. 11-006170, LNA RF Circuit Diagram
- 5.1.4.5Drg. No. 11-006171, LNA DC Wiring Diagram
- 5.1.4.6Drg. No. 11-003971, LNA DC Schematic Diagram
- 5.1.4.7Technical Specification (11-007302)
- 5.1.4.8Drg. No. 11-007302, LNA Assembly With Alarm Relay
- 5.1.4.9Drg. No. 11-007370, LNA RF Circuit Diagram
- 5.1.4.10Drg. No. 11-007371, LNA DC Wiring Diagram
- 5.1.4.11Technical Specification (11-007402)
- 5.1.4.12Drg. No. 11-007402, LNA General Assembly
- 5.1.4.13Drg. No. 11-007470, LNA RF Circuit Diagram
- 5.1.4.14Drg. No. 11-007471 LNA DC Wiring Diagram
- 5.1.55Watt Power Amplifier (12-001801)
- 5.1.5.1Description
- 5.1.5.2Technical Specification
- 5.1.5.3Drg. No. 12-001801, 5Watt PA General Assembly Drawing
- 5.1.5.4Drg. No. 12-001870, 5Watt PA Circuit Diagram
- 5.1.5.5Drg. No. 12-001870C1, 5W PA Component List(1)
- 5.1.5.6Drg. No. 12-001870C2, 5W PA Component List(2)
- 5.1.5.7Drg. No. 80-008450, Power Amplifier/Alarm Board DC Wiring Details
- 5.1.63 Stage Amplifier Alarm Boards (12-002201)
- 5.1.7DC/DC Converter, 24V in, 12V 8A out (13-003011)
- 5.1.8Channel Selective & Channel Control Modules (17-003012 & 17-002101)
- 5.1.8.1Channel Selective Module Description
- 5.1.8.2Drg. No. 17-003080, Generic Channel Module Block Diagram
- 5.1.8.3Channel Selectivity Control Module Description
- 5.1.8.4Channel Controller DIP Switch Configuration Frequencies
- 5.1.8.5UHF1 Downlink Channel Module Configuration Table
- 5.1.8.6UHF1 Uplink Channel Module Configuration Table
- 5.1.8.7UHF1A Downlink Channel Module Configuration Table
- 5.1.8.8UHF1A Uplink Channel Module Configuration Table
- 5.1.8.9UHF2 Downlink Channel Module Configuration Table
- 5.1.8.10UHF2 Uplink Channel Module Configuration Table
- 5.1.9Single & Dual 24Volt Relay Boards (20-001602 & 80-008902)
- 5.1.10SMA coaxial termination (93-930003)
- 5.1.1124V 400W Flat-Pack Power Supply (96-300011)
- 5.2UHF 2 Air Interface (60-055902)
- 5.2.1Bandpass Filter (02-013401) See section 5.1.1
- 5.2.24 Port Tx Hybrid Combiner (05-003019)
- 5.2.3Four Way Low Power Splitter (05-003401) See section 5.1.2
- 5.2.4¼Watt 0- -30dB Switched Attenuator \(10-00
- 5.2.5Low Noise Amplifiers (11-007302 & 11-007402) See section 5.1.4
- 5.2.63 Stage Amplifier Alarm Boards (12-002201) See section 5.1.6
- 5.2.720Watt Power Amplifier (12-004201)
- 5.2.8DC/DC Converter, 24V in, 12V 8A out (13-003011) See section 5.1.7
- 5.2.9Chan. Selec. & Chan. Contr. Mdls (17-003012 & 17-002101) See section 5.1.8
- 5.2.1021MHz IF Filter Board (17-002502)
- 5.2.11Single & Dual 24Volt Relay Boards (20-001602 & 80-008902) See section 5.1.9
- 5.2.12SMA Coaxial Termination (93-930003) See section 5.1.10
- 5.2.1324V 400W Flat-Pack Power Supply (96-300011) See section 5.1.11
- 5.2.14JWS75-15/A PSU (96-300045)
- 5.2.15Single Mode Optical Coupler (98-100001)
- 5.2.16.Fibre Optic Receiver & Transmitter (98-200003 & 98-300003)
- 5.3UHF1A 60-055903 470MHz 3 Channel BDA
- 5.1UHF 1 Air Interface (60-055901)
- 6.INSTALLATION
- 7.MAINTENANCE
- APPENDIX AINITIAL EQUIPMENT SET-UP CALCULATIONS
PBL UHF1/1A 1 & 2 Air Interface
Maintenance Handbook
H/book Number:-60-055900HBKM
Issue No:-2
Date:-20/10/2003
Page:-
51 of 85
5.1.6 3 Stage Amplifier Alarm Boards (12-002201)
5.1.6.1 Description
Amplifier Alarm Boards are fitted to monitor the bias conditions of AFL Class A
amplifiers which remain constant in normal operation. Any departure from normal bias
conditions is a result of device failure, excess temperature, over-driving or oscillation
(excessive power).
In normal operation, the Class A bias circuit of the amplifier develops a constant voltage
of 1.20V across the collector current setting resistor. The Amplifier Alarm Board is a
window comparator device, which is adjusted to sense a departure from this condition.
Several different alarm outputs are provided to simplify interfacing, (Relay Contact, Open
Collector, and TTL Logic Levels)
The basic version of the Alarm Board (12-002801) monitors a single amplifier stage. A
three-stage version (12-002201) is used on complex amplifiers where three separate
comparators have their outputs logically combined to a common output stage. Failure of
any one stage will activate the alarms.
Note that the alarm board has a green Light Emitting Diode located near to the centre of
the printed circuit board, which is illuminated on ‘Good’, and extinguished on ‘Alarm’. It
is therefore a simple matter to identify an active module failure, by searching for an
Alarm Board which has its green LED extinguished. A simple test of the alarm board is
possible by shorting across the monitor inputs, pins 1 and 2, 3 and 4 or across pins 5 and
6. This last monitor input is inactive if the board has been converted to a two way alarm
board. (Refer to relevant amplifier alarm wiring diagram.)
1) Volt-free change over relay contacts.
2) Open collector NPN transistor pulls low on alarm.
3) TTL driver.
The use of precision voltage sources and resistors has eliminated the need for initial
adjustment or calibration, and the board will function correctly with a wide variation in
power supply voltage (8 to 30 volts, nominal supply is 12 or 24Volts).
There are two selectable link options on the three-way board:
LINK1 - Removed to convert to two-way alarm board.
LINK2 - Removed to isolate 0V from chassis earth.
The one way alarm board only has the 0V isolation link (LINK2) fitted.