User Manual
Table Of Contents
- 1. INTRODUCTION
- 1.1. Scope and Purpose of Document
- 1.2. Limitation of Liability Notice
- 2. SAFETY CONSIDERATIONS
- 3. EQUIPMENT OVERVIEW
- 4. UHF BANDSELECTIVE, BDA (55-199102) SUB MODULES
- 4.1. Bandpass Filter (02-010701)
- 4.2. 3dB Splitter/Combiner (05-002603)
- 4.3. Remote Attenuator Switch Assembly (‘10-001725’)
- 4.4. 5 Watt Tetra Amplifier (12-021601)
- 4.5. Linearised Power Amplifier (12-026901)
- _
- 4.6. Voltage Regulator Board 9.0V (13-001714)
- 4.7. DC/DC Converter, 24V in, 12V 8A out (13-003011)
- 4.8. Bi-Directional Amplifier (17-017301)
- 4.9. 12V (Single) Relay Board (80-008901)
- 4.10. 24V Switch-Mode PSU (96-300054)
- 5. INSTALLATION & COMMISIONING
- 6. FAULT FINDING / MAINTENANCE
- 6.1. Tools & Test Equipment
- 6.2. Basic Fault Finding
- 6.3. Quick Fault Checklist
- 6.4. Downlink
- 6.5. Uplink
- 6.6. Fault repair
- 6.7. Service Support
- 6.8. Care of Modules
- 6.9. Module Removal (LNAs, general procedure):
- 6.10. Module Replacement (general):
- 6.11. Power Amplifiers
- 6.12. Low Power Amplifier Replacement
- 6.13. Module Transportation:
- APPENDIX A
- _
- _
- APPENDIX B
4.4. 5 Watt Tetra Amplifier (12-021601)
The power amplifier fitted to this unit is a multi-stage, solid state power amplifier. Class A circuitry is
employed throughout the device to ensure excellent linearity over a wide dynamic frequency range.
All the semi-conductor devices are very conservatively rated to ensure low device junction
temperatures and a long, trouble free working lifetime.
The power amplifier should require no maintenance over its operating life. Under no circumstances
should the cover be removed or the side adjustments disturbed unless it is certain that the amplifier
has failed; since it is critically aligned during manufacture and any re-alignment will require extensive
test equipment.
The unit housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF
input/output and a D-Type connector for the power supply and the Current Fault Alarm Function.
12-021601 Specification
PARAMETER SPECIFICATION
Frequency range: 380-470MHz (as required)
Bandwidth: 10-40MHz (typical, tuned to spec.)
Maximum RF output: >5Watts
Gain: >30dB
1dB compression point: +37.5dBm
3
rd
order intercept point: +50dBm
VSWR: better than 1.5:1
Connectors: SMA female
Supply: 1.9Amps @ 12V DC
Weight: 1kg (excluding heatsink)
operational:
-10°C to +60°C Temperature
range:
storage:
-20°C to +70°C
7-Way Connector Pin-out details
Connector Pin Signal
A1 (large pin) +10-24V DC
A2 (large pin) GND
1 Alarm relay common
2 TTL alarm/0V good
3 Alarm relay contact (bad)
4 Alarm relay contact (good)
5 O/C good/0V bad (TTL)
7-Way Pin-Out Graphical Representation
A1 A2
1 2
3 4 5
UHF Bandselective BDA
90dB 40/5W
Document Number 55-199102HBKM Issue No. 1 Page 14 of 28