User Manual
Table Of Contents
- 1. INTRODUCTION
- Scope and Purpose of Document
- Limitation of Liability Notice
- 2. SAFETY CONSIDERATIONS
- 3. EQUIPMENT OVERVIEW
- 4. SUB-UNIT MODULES
- 4.1 Bandpass Filter (02-010201)
- 4.2 Two-Way Splitter (07-002503)
- 4.3 0.25Watt 0- -30dB Switched Attenuator (10-000703)
- 4.4 11-007302 & 11-007402 Low Noise Amplifiers
- 4.4.1 Description
- 4.4.2 Technical Specification (11-007302)
- 4.4.3 Technical Specification (11-007402)
- 4.4.4 LNA ‘D’ Connector Pin-out details
- 4.4.5 Drg. # 11-007302, LNA Assembly With Alarm Relay
- 4.4.6 Drg. # 11-007370, LNA RF Circuit Diagram
- 4.4.7 Drg. # 11-007371, LNA DC Wiring Diagram
- 4.4.8 Drg. # 11-003971, LNA DC Circuit Diagram
- 4.4.9 Drg. # 11-007402, LNA Assembly With Alarm Relay
- 4.4.10 Drg. # 11-007470, LNA RF Circuit Diagram
- 4.5 12-021601 5Watt Medium Power Tetra Amplifier
- 4.6 12-022101 10Watt Power Tetra Amplifier
- 4.7 8A Mains Filter Assembly (13-003301)
- 4.8 Channel Control Module (17-002101)
- 4.9 Channel Selective Module (17-003007)
- 4.10 12V Single Relay Board (80-008901)
- 4.11 12V Switch-Mode PSU (96-300052)
- 5. INSTALLATION
- 6. FAULT FINDING & MAINTENANCE
- 6.1 General Fault Finding Procedures
- 6.2 Downlink
- 6.3 Uplink
- 6.4 Fault repair
- 6.5 Checking service
- 6.6 Service Support
- 6.7 Tools & Test Equipment
- 6.8 General Maintenance Procedures
- _
- 6.9 Module Removal (LNA’s, general procedure)
- 6.10 Module Replacement (general)
- 6.11 Power Amplifiers
- 6.12 Low Power Amplifier Replacement
- 6.13 Module Transportation
- APPENDIX A
- _
- APPENDIX B
Two Channel UHF Cell Enhancer
User Handbook
Handbook Number: 50-187601HBKM Page: 42 of 51
4.11 12V Switch-Mode PSU (96-300052)
4.11.1 Description
The power supply unit is a switched-mode type capable of supplying 12V DC at 12.5Amps
continuously. This unit will draw approximately 7-8Amps at 12V DC, so the PSU’s will be used
conservatively ensuring a long operational lifetime.
No routine maintenance of the PSU’s is required. If a fault is suspected, then the output voltage from
the power supply may be measured on its output terminals. This is typically set to 12.2V. The
adjustment potentiometer will be found close to the DC output terminals.
All the PSU’s used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal
AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by
the operator.
4.11.2 Technical Specification
AC Input Supply
110 or 220V nominal
Voltage:
90 to 132 or 180 to 264V
(absolute limits)
Frequency: 47 to 63Hz
DC Output Supply
12V DC (nominal)
Voltage:
10.5-13.8V (absolute limits)
Current: 12.5A