User Manual
Table Of Contents
- 1. INTRODUCTION
- 1.1. Scope and Purpose of Document
- 1.2. Limitation of Liability Notice
- 2. SAFETY CONSIDERATIONS
- 3. Equipment Overview
- 4 15 Channel Repeater 50-157401 Major Sub-Components
- 4.1. Downlink Splitter/Combiner 50-157402
- 4.2. Channel Module Shelf 50-157403 (6 channels)
- 4.3. Channel Module Shelf 50-157404 (3 channels)
- 4.4. 100W Power Amplifier 80-245103
- 4.5. Uplink Triplexer Shelves 50-157405
- 4.7. Uplink 5W Amplifier Shelf 50-157406
- 4.7.2. Uplink 5W Amplifier Shelf 50-157406 Specification
- PARAMETER
- SPECIFICATION
- 5. INSTALLATION
- 6. Fault Finding & MAINTENANCE
- 6.1 General Fault Finding Procedures
- 6.2 Downlink
- 6.3 Uplink
- 6.4 Fault repair
- 6.5 Checking service
- 6.6 Service Support
- 6.7 Tools & Test Equipment
- 6.8 General Maintenance Procedures
- 6.9 Module Removal (LNAs, general procedure)
- 6.10 Module Replacement (general)
- 6.11 Power Amplifiers
- 6.12 Low Power Amplifier Replacement
- 6.13 Module Transportation
- Appendix A
- _
- _
- Appendix B
Axell Wireless Limited
Technical Literature
15 Channel UHF Hybrid Select Repeater
Document Number 50-157401HBK Issue No. 1 Date 26/03/2008 Page 6 of 50
2.5. Chemical Hazard
Beryllium Oxide, also known as Beryllium Monoxide, or Thermalox™, is sometimes
used in devices within equipment produced by Axell Wireless Ltd. Beryllium oxide dust
can be toxic if inhaled, leading to chronic respiratory problems. It is harmless if
ingested or by contact.
Products that contain beryllium are load terminations (dummy loads) and some power amplifiers.
These products can be identified by a yellow and black “skull and crossbones” danger symbol (shown
above). They are marked as hazardous in line with international regulations, but pose no threat under
normal circumstances. Only if a component containing beryllium oxide has suffered catastrophic
failure, or exploded, will there be any danger of the formation of dust. Any dust that has been created
will be contained within the equipment module as long as the module remains sealed. For this reason,
any module carrying the yellow and black danger sign should not be opened. If the equipment is
suspected of failure, or is at the end of its life-cycle, it must be returned to Axell Wireless Ltd. for
disposal.
To return such equipment, please contact the Quality Department, who will give you a Returned
Materials Authorisation (RMA) number. Please quote this number on the packing documents, and on
all correspondence relating to the shipment.
PolyTetraFluoroEthylene, (P.T.F.E.) and P.T.F.E. Composite Materials
Many modules/components in AWL equipment contain P.T.F.E. as part of the RF insulation barrier.
This material should never be heated to the point where smoke or fumes are evolved. Any person
feeling drowsy after coming into contact with P.T.F.E. especially dust or fumes should seek medical
attention.
2.6. Laser safety
General good working practices
adapted from EN60825-2: 2004/ EC 60825-2:2004
Do not stare with unprotected eyes or with any unapproved optical device at the fibre
ends or connector faces or point them at other people, Use only approved filtered or
attenuating viewing aids.
Any single or multiple fibre end or ends found not to be terminated (for example, matched, spliced)
shall be individually or collectively covered when not being worked on. They shall not be readily
visible and sharp ends shall not be exposed.
When using test cords, the optical power source shall be the last connected and the first
disconnected; use only approved methods for cleaning and preparing optical fibres and optical
connectors.
Always keep optical connectors covered to avoid physical damage and do not allow any dirt/foreign
material ingress on the optical connector bulkheads.
The optical fibre jumper cable maximum bend radius is 3cm; any smaller radii may result in optical
cable breakage or excessive transmission losses.
Caution: The FO units are NOT
weather proof.
2.7. Emergency Contact Numbers
The AWL Quality Department can be contacted on:
Telephone +44 (0)1494 777000
Fax. +44 (0)1494 777002
e-mail
qa@axellwireless.com