Handbook

Table Of Contents
Denver Channelised CE
User/Maintenance Handbook
Handbook Nō.-50-063708HBKM Issue No:-2
Date:-03/11/2003
Page:-
44 of 51
5.6 Power Supply Shelf 50-063707
5.6.1 24V, 400W Power Supply Pack (96-300054)
5.6.1.1 Description
The power supply unit is a switched-mode type capable of supplying 24V DC at 17.0Amps
continuously. Equipment of this type typically requires approximately 10.0 Amps at 24V
DC, so the PSU will be used conservatively ensuring a long operational lifetime.
No routine maintenance of the PSU is required. If a fault is suspected, then the output
voltage from the power supply may be measured on its output terminals. This is typically set
to 24.5V using the multi-turn potentiometer mounted close to the DC output studs on the
PSU PCB.
All the PSU’s used in AFL Cell Enhancers are capable of operation from either 110 or
220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or
link setting is needed by the operator.
5.6.1.1 Technical Specification
AC Input Supply
110 or 220V nominal
Voltages:
90 to 132 or 180 to 264V (absolute limits)
Frequency: 47 to 63Hz
DC Output Supply:
24V DC (nominal)
Voltage:
20 to 28V (absolute limits)
Maximum current: 17A
All other modules in this shelf are described elsewhere in this document.