User Manual
Table Of Contents
- AMENDMENT LIST RECORD SHEET
- INTRODUCTION
- 1.SAFETY CONSIDERATIONS
- 2.OVERVIEW/SYSTEM DESCRIPTION
- 3.SPECIFICATION
- 4.SYSTEM DRAWINGS
- 5.SUB-UNIT MODULES
- 5.1VTA Downlink Duplexer Shelf 60-025302 (4U chassis)
- 5.2VTA Downlink Amplifier Shelf (50-025303, 8U Chassis)
- 5.2.1UHF 3dB Splitter (05-002603)
- 5.2.2¼Watt 0- -30dB Switched Attenuator \(10-00
- 5.2.3Low Noise Amplifier (11-006102)
- 5.2.4Low Noise Amplifiers (11-007302 & 11-007402)
- 5.2.4.1Description
- 5.2.4.2Technical Specification, (11-007302)
- 5.2.4.3Technical Specification (11-007402)
- 5.2.4.4Drg. No. 11-007302, LNA Assembly With Alarm Relay
- 5.2.4.5Drg. No. 11-007370, LNA RF Circuit Diagram
- 5.2.4.6Drg. No. 11-007371, LNA DC Wiring Diagram
- 5.2.5.7Drg. No. 11-003971, LNA DC Circuit Diagram
- 5.2.63 Stage Amplifier Alarm Boards (12-002201)
- 5.2.7450MHz 20W Power Amplifier (12-004201)
- 5.2.8Single DC/DC Converter (13-001702)
- 5.2.924V Single Relay Board (80-008902)
- 5.2.1024V 410W Power Supply (96-300054)
- 5.3VTA Downlink Channel Shelf (50-025304)
- 5.4VTA Uplink Duplexer Shelf (50-025305, 4U Chassis)
- 5.5VTA Uplink Amplifier Shelf (50-025306, 8U Chassis)
- 5.5.120Watt Class A Power Amplifier (12-016301)
- 5.5.2Automatic Gain Control (17-001101, Det. & 17-001201, Atten.)
- 5.5.2.1Description
- 5.5.2.2Technical Specification
- 5.5.2.3Drg. No. 17-001101, ACG Detector Assembly
- 5.5.2.4Drg. No. 17-001171, AGC Detector Circuit Diagram
- 5.5.2.5Drg. No. 17-001171C, AGC Detector Parts List
- 5.5.2.6Drg. No. 17-001201, AGC Attenuator Assembly Drawing
- 5.5.2.7Drg. No. 17-001270, AGC Attenuator Circuit Diagram
- 5.5.2.8Drg. No. 17-001270C, AGC Attenuator Parts List
- 6.INSTALLATION
- 7.MAINTENANCE
- APPENDIX AINITIAL EQUIPMENT SET-UP CALCULATIONS
9 Way Channelised UHF Cell Enhancer
Maintenance Handbook
H/book Number:-50-025301HBKM
Issue No:-
1
Date:-04/07/2003
Page:-
46 of 69
5.2.10 24V 410W Power Supply (96-300054)
5.2.10.1 Description
The power supply unit is a switched-mode type capable of supplying 24V DC at 17.0Amps
continuously. Equipment of this type typically requires approximately 8.0 Amps at 24V DC,
so the PSU will be used conservatively ensuring a long operational lifetime.
No routine maintenance of the PSU is required. If a fault is suspected, then the output
voltage from the power supply may be measured on its output terminals. This is typically set
to 24.5V.
All the PSU’s used in AFL Cell Enhancers are capable of operation from either 110 or 220V
nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link
setting is needed by the operator. No drawings of the PSU are available.
5.2.10.2 Technical Specification
AC Input Supply:
Voltage: 110 or 220V nominal - 90 to 132 or 180 to
264V (single phase, absolute limits)
Frequency: 47 to 63Hz
DC Output Supply:
Voltage: 24V DC (nominal), 22 to 26V
(absolute limits)
Current: 17.0A
operational:
-10ΒC to +55ΒC
Temperature
range:
storage:
-40ΒC to +70ΒC