Specifications
SAFETY WARNINGS ENG
Pag. 6
3.1 AC MAINS VOLTAGE SETTING (220 V / 115 V)
BE SURE THAT THE UNIT IS SET TO THE CORRECT MAINS/LINE VOLTAGE FOR
YOUR COUNTRY BEFORE PLUGGING IT INTO THE WALL OUTLET.
The actual Mains voltage is indicated on the silver label
stuck on the right side of the Parrot closure.
If, for some reason, the unit is to be operated at a mains input voltage which is different to that as supplied,
you need to open the top cover and set properly the voltage change-over switch
which is located inside,
close to the transformer (on the right hand). You also need to replace the AC main fuse (for 220/230 V AC
the fuse is rated at 630mA T; for 110 V AC voltage it is rated at 1 A T)
3.2 RACK MOUNTING THE UNIT
To mount the unit in a standard 483 mm (19-inch) audio equipment rack, slide the equipment into the rack
and secure it with crosshead screws, as shown in the figure. Use all four screws.
Ventilation. Slots and openings in the product are provided for ventilation. They ensure reliable operation of
the product, keeping it from overheating. These openings must not be blocked nor covered during operation.
You must leave at a minimum one rack unit of
empty space above the Parrot to enhance
ventilation and to get a longer equipment life.
Install a 1U vented or blind panel to fill this space. It
is recommended that another 1RU blank panel be
installed below the unit
for the same reason.
There should be a good ground connection between the rack and the Parrot chassis