User manual
TELEPHONE CHANNELS (OXYGEN 3 and 3 ST)
ENG
Axel Technology srl www.axeltechnology.com TELEPHONE CHANNELS
(OXYGEN 3 and 3 ST)
24
17.1 ALIGNEMENT OF INPUTS
When plugging in a new source start with the fader turned down and the PFL activated. The signal is displayed on the
meters on the left hand (PFL) and can be checked in the headphones or in the Monitor loudspeakers.
Adjust the channel GAIN control for an average channel meter reading of „0‟ with loud moments lighting „+3‟.
Reduce the gain if the signal meter always ranges in the 0 to + 3dB area. It may be necessary to re-adjust the gain if
changes are made to the equaliser.