Specifications
Macrotel DIGITAL
Pag. 9
3.3 REMOTE INTERFACE
Remote Connector Pinout
Pin Description
1 Remote Hybrid On
2 Remote Hybrid Off
3 Not used
4 Not used
5 Switch / Indicator Common
6 Not used
7 Not used
8 + 5 Volt dc (supplied via an internal 100 Ohm protection resistor)
9 Unbalanced AUX –IN Audio Input (0dBu nominal)
10 Unbalanced Receive Audio Output (0dBu nominal)
11 Unbalanced Rec Audio Output (0dBu nominal)
12 Monitor Mute Control*
13 Audio Common
14 Hybrid On Indication
15 Hybrid Off Indication
16 Not used
17 Not used
18 Switch/Indicator Common
19 Hybrid Send Presence Indicator
20 Hybrid Receive Presence Indicator
21 Switch/Indicator Common
22 Audio Common
23 Audio Common
24 Audio Common
25 Switch/Indicator Common
* Remote control provided via contact closure to Switch/Indicator
Common
** Remote indicators provided via open collector outputs to Indicator
Common (<15V, <39mA)
3.4 TEL LINE CONNECTION
Macrotel Digital hybrid operates on standard POTS (Plain Old Telephone Service) / PSTN (Public Switched
Telephone Network) analog telephone lines
or an analog extension from a PBX via a standard RJ11
modular jack.
The RJ11 socket will accept 6 conductor modular plugs, but only the 2 central conductors
(typically Red &
Green ) are used.