User manual

COMMUNICATION PORTS AND GPI/O WIRING
ENG
Page 39
19.7 GP OUTPUT INTERFACE
Inputs
The Falcon 50 provides a general purpose output (GPO) interface for signalling or
controlling external equipment. The pinout for the GPO connector (DB15 Male)
is provided in the following chart. All inputs and outputs are opto-isolated for
reliable operation in a variety of electrical environments. There are four outputs.
R
R
R
R
Rv
OUT1
OUT1
OUT2
OUT2
OUT3
OUT3
OUT4
OUT4
+12 V
12
5
4
1
2
3
6
9
10
11
13
PIN
DESCRIPTION DIRECT.
PIN
DESCRIPTION DIRECT.
1 Collector of photocoupler output 1 OUT
9 Emitter of photocoupler output 1
OUT
2 Collector of photocoupler output 2 OUT
10 Emitter of photocoupler output 2
OUT
3 Collector of photocoupler output 3 OUT
11 Emitter of photocoupler output 3
OUT
4 + 12 V via 100 Ohm resistor OUT
12 GND /
5 + 12 V via 100 Ohm resistor OUT
13 Emitter of photocoupler output 4
IN
6 Collector of photocoupler output 4 OUT
14 N.C. /
7 N.C. /
15 N.C. /
8 N.C. /
Each optoisolator is capable of sinking up to 60 mA of current.
OUTPUTS # 1 AND # 2 can be associated to a variety of events (Temperature exceeding 60 or 70 Celsius
Degrees, Failures one audio inputs, etc) in order to provide ALARM signallings to external devices by means
of Contact closures. Ref. to the User Manual – PART TWO
OUTPUTS # 3 AND # 4 are directly driven via software from external controlling devices or systems (such as
automated radio systems) running a suitable Remote Control protocol.