User`s manual

Remote Administration
AX3000 - User's Manual 215
ERR 103: trailer label not found. Default factory set-up reloaded
Command: setup_send
Cause: the trailer label (END_AX_SETUP) is not found. (Either this
label is not included in the configuration file or the
connection failed).
Consequence: the default factory set-up is reloaded (to replace the
inconsistent configuration caused by the missing trailer
label).
Solution: add this label to the end of file and run the command again.
ERR 104: Can not get complete set-up (rcmd command aborted).
Command: setup_get
Cause: a network problem has occurred or the command has been
killed or aborted.
Consequence: the set-up obtained by the command is invalid (the trailer
label is missing).
Solution: run the command again.
ERR 105: invalid rcmd command.
Command: ---
Cause: the keyword is unknown.
Consequence: no effect.
Solution: use the correct keyword (setup_send, setup_get or
ax_reboot).
ERR 106: cmos busy.
Command: setup_send
Cause: another command (setup_get or setup_send) is running, or
another user has entered set-up on the target AX3000.
Consequence: no effect.
Solution: Either wait for a few seconds and repeat the command, or
arrange for the other user to exit set-up on the target
AX3000.