Command Description
23c Set serial data rate to 4800 baud
24c Set serial data rate to 9600 baud
25c Set serial data rate to 19200 baud (default)
18c Set tag read serial output to ON; i.e. output tag read data (default)
32c Set tag read output to OFF; i.e. disable tag read data output
21c Set serial output to the long format RRRAAAFFFTTTTT (default) where RRR=
Receiver ID, AAA = Activator ID or Status Code, FFF = Facility Code, TTTTT = Tag ID
36c Set serial output to short format AAAFFFTTTTT where AAA = Activator ID or Status Code,
FFF = Facility Code, TTTTT = Tag ID
Configure/Control Wiegand Output
Command Description
15c Set Wiegand output to ON; i.e. report tag read data via Wiegand port. (default)
29c Set Wiegand output to OFF
<number>W Set single valid Wiegand Activator ID; valid numbers = 1 thru 250 (default)
<number>L Set tag redundancy buffer time in tenths of seconds; valid numbers = 0 thru 255
(default = 125 or 12.5 seconds)
<number>T Set time between tag read outputs in tenths of seconds; valid numbers = 0 thru 255
(default = 13 or 1.3 seconds)
19c Set Wiegand Activator ID filter to ON, i.e. output only tag data valid per the Wiegand
Activator ID as set by the <number>W command (default)
33c Set Wiegand Activator ID filter to OFF, i.e. outputs all tag reads validated by both the
Wiegand ID and the Valid ID list
12c Set Wiegand alarm output to OFF; i.e. do not output data if Status Code = 000
(default)
26c Set Wiegand alarm output to ON; i.e. output tag data when Status Code = 000
41c Enables the Wiegand ID list
42c Disables the Wiegand ID list
43c Clears Valid Wiegand ID list (except ID number 127)
44c Sets the Valid Wiegand ID list to default values (per V5 list)
<number> > Add new Device ID or Status Code to the Valid Wiegand ID list (0 thru 255, max. 34
entries)
<number> < Delete a Device ID or Status Code to the Valid Wiegand ID list (0 thru 255, min. 1 entry)
NOTE The Wiegand filters, buffers and settings do not affect the serial output. Unless Wiegand
output is set to ON via command “15c”, no data will be output via Wiegand regardless of the other
settings.