Installation Guide
© 2002, AXCESS Inc. 750.001.005 R0000 17
Responding to Activator IDs
The Receiver will only output Tag data via the serial port if it
contains a valid Activator ID.
By default, The Network Receiver accepts Tag data from
Activators with the following IDs:
0 3 13 14 21 22
24 27 33 34 44 47
52 55 57 58 69 70
72 75 80 83 93 94
100 103 105 106 113 114
124 127 254 255
Figure 5 Default Activator IDs
Editing Activator IDs within the Receiver
Use the following commands to add, delete and reset the
Activator ID numbers within the Receiver:
Command Action
<number>- Delete unwanted ID(s) from the Receiver’s list
37c Remove all accepted Activator IDs
(Receiver will still pass default ID 127)
<number>+ Add an Activator ID
34c Reset the list to the valid Activator ID numbers
When editing the Activator IDs within the Receiver, you may
observe the following error codes.
Code Reason
04 Trying to delete an ID that has not been
programmed
03 Trying to delete all IDs. Must be at least one ID.
02 Trying to enter more than 34 IDs – the max.
(Delete some Activator IDs on the list to make room)
01 Duplicate entry