Signal Name Backplane Backplane Signal Type Description
Control/Remote Pin
Standby CMD (FA) J19-29C J12-1 Discrete open collector input Low indicates FA requests the xmrt go to standby
Operate CMD (FA) J19-30C J12-3 Discrete open collector input Low indicates FA requests the xmrt go to operate
Aural / Visual Mute (FA) J19-31C J12-5 Discrete open collector input Low indicates FA requests an aural visual mute
Visual Mute (FA) J19-32C J12-3 spare input
Ext Ref Present (FA) J19-2B J12-9 spare input
ABS Standby CMD J19-3B J12-11 Discrete open collector input Low indicates FA requests the xmtr go to standby
EXT Operate output J19-4B J12-13 Discrete open collector input Low enables ext amp when xmtr goes to operate.
EXT Visual ALC Input J19-5B J12-15 spare input
XMTR Interlock Iso Return J19-6B J12-18 Ground Ground return. Can be jumpered directly to gnd
or source pin of FET so the xmtr interlock can be
daisy chanied w/ an external amp
XMTR Interlock J19-7B J12-19 Discrete open collector input low indicates xmtr interlock and no faults
EXT O/P Amp Mod Status J19-8B J12-24, J13-23 Discrete open collector input low indicates external amp fault
EXT P.S. Status Amo O/P J19-9B J12-26, J13-24 Discrete open collector input low indicates external amp power supply failure
Operate Ind J19-10B J12-31 Discrete open collector input low indicates xmtr is in operate mode
EXT Overtemp (Amp) I/P J19-11B J12-33, J13-20 Discrete open collector input low indicates ext amp above normal temperature
EXT Refl Pwr (Amp) I/P J19-13B J12-37, J13-20 Discrete open collector input indicates reflected power of the remote amplifier
Standby CMD (RCVR) J19-14B J12-29 Discrete open collector input low indicates external RCVR requests xmtr go
into standby mode
Operate CMD (RCVR) J19-15B J12-29 Discrete open collector input low indicates external RCVR reguests xmtr go
into operate mode
RMT Operate Indicator J19-17B J13-4 Discrete open collector input low indicates xmtr is in operate
O/P Amp Mod Status O/P J19-18B J13-7 Discrete open collector input low indicates no faults in the amp mod
RMT FWD Power O/P J19-19B J13-8 Analog O/P 0-1.25V loop through from IF proc, indicates fwd o/p pwr
RMT REFL Power J19-20B J13-12 Analog O/P 0-1.25V loop through from pwr amp mod’s refl pwr
RMT XMTR Fault Ind J19-21B J13-14 Discrete open collector input low indicates xmtr fault
IF Present Status O/P J19-22B J13-15 Discrete open collector input low indicates no IF to the IF processor module
RMT PLL Locked Ind O/P J19-23B J13-16 Discrete open collector input low indicates freq gen / upconv is unlocked
RMT XMTR Overtmp Ind J19-24B J13-18 Discrete open collector input low indicates xmtr pwr amp above normaltemp
P.S. Fault Indicator J19-25B J13-19 Discrete open collector input low indicates xmtr P.S. failure
EXT PLL Ref Present O/P J19-26B J13-25 Discrete open collector input low indicates loss of 10MHz reference
RMT XMTR J19-24A J13-3 Discrete open collector input low indicates remote interface requests xmtr go to
Standby CMD standby
RMT XMTR J19-25A J13-1 Discrete open collector input low indicates remote interface requests xmtr go to
Operate CMD operate