User's Manual Part 1
OPERATION
Initial Turn On
Once all connections have been made and the unit has been installed, the process of turning
on the equipment can begin. First verify that AC power is present and connected to each
transmitter. Verify all cables are properly connected and the correct type. Once all of these
things are done, the unit is ready to be turned on following the procedures below.
Turn on the main AC power source that supplies the
entire system. Turn on the AC circuit breaker (CB1) on the
back of each unit.
Verify that each unit is showing the display as indicated
in the diagram. (Note: Some models may display ADC
TELECOMMUNICATIONS).
When the transmitter is in operate mode, the STB menu ap
pears. In standby mode, the OPR menu appears. Press the
NXT key after each menu to continue through the sequence
that follows.
AXCERA V 2.5
LLC
MODEL: 5724
RF CHANNEL: A1
STB STS PRV
VERSION 2.5
SCADA ADDRESS: 32
STB STS PRV
If the SCADA option is selected, the unit will display the
version number and SCADA address.
Next, the unit will display percentage output power.
OUTPUT PWR 75%
0 50 100
STB STS PRV
REFLECTED PWR 10%
0 50 100
STB STS PRV
Percentage reflected power screen.
EXT OUTPUT PWR 75%
0 50 100
STB STS PRV
External amplifier output power (if external amp
present)
18