Operating instructions

2-6
To cancel a regeneration (either manual or automatic):
• Press and hold the SET button and UP buttons simultaneously and hold until the hourglass icon starts fl ashing
(approximately 5 seconds).
The regeneration is cancelled.
The camshaft rotates to the treated water position (may take up to 2 min.)
• Hourglass fl ashes while motor runs.
If a second regeneration was programmed (display shows a 2X by the regeneration icon) both regenerations
must be cancelled separately.
WARNING: Cancelling a regeneration may cause undesirable or salty water to go into the plumbing.
Only use this function when absolutely necessary.
CAUTION: If the regeneration cycle is cancelled after the brine draw cycle (C2), check the water level in
the brine tank. It must be refi lled to the proper level.
MANUAL REGENERATION
Action Key Duration Display
Regen at next time of regen REGEN P/R Recycle icon fl ashes
Cancel regen REGEN P/R when recycle Recycle icon disappears
icon is fl ashing
Immediate regen REGEN 5 sec. Recycle icon appears
Immediate double regen REGEN 5 sec. when X2 icon appears
immediate manual
regen has started
The controller can be manually instructed to perform a regeneration. There are two (2) choices: The controller
will perform a delayed regeneration at the next time of regeneration (ex. 2:00 AM that night), or regenerate im-
mediately.
For a delayed regeneration (at the next set time of regeneration):
• Push the REGEN button once. The recycle symbol will be fl ashing on the display. Push the REGEN button
again to cancel.
For an immediate regeneration:
• Push and hold the REGEN button for fi ve (5) seconds. The display will show the regeneration symbol. The
camshaft will start rotating to cycle C1.
For an immediate, double regeneration:
• After an immediate manual regeneration has begun, and the camshaft has rotated to cycle C1, you can initiate
a second immediate manual regeneration.
• Press and hold the REGEN button for 5 seconds once the camshaft has begun cycle C1.
The display will show a x2 icon indication that a second manual regeneration will occur after the current regen-
eration is completed.