Operating instructions

2-5
REGENERATION MODES
The AWS series controllers can be regenerated either automatically or manually. During a regeneration, the total
time remaining of the regeneration, the total time remaining of the regeneration will be displayed on the controller.
The current cycle is shown in the lower left of the display.
Regeneration Cycle Indicators
C0 = Treated Water - normal operation mode (not displayed)
C1 = Backwash Cycle
C2 = Brine Draw Cycle
C3 = Slow Rinse Cycle
C4 = System Pause
C5 = Fast Rinse Cycle 1
C6 = Backwash Cycle 2
C7 = Fast Rinse Cycle 2
C8 = Brine Refi ll
Advancing the Regeneration Cycles
Action Key Duration Display
Show current cycle SET HOLD Cx
Show regen time remaining SET HOLD Time
Advance to next cycle SET and UP HOLD Cx
To advance cycles during a regeneration (manual or automatic):
• Press and hold the SET button. The current cycle number, (Ex. C1) will be displayed along with the time remain-
ing for that individual cycle.
When holding the SET button, simultaneously press the UP button, and release to advance to the next cycle.
While the motor is running, an hourglass icon will be displayed.
• Repeat this process for each cycle until the system is back into the treated water mode.
NOTE: When the controller gets to cycle C4 (Pause cycle), there may be a slight delay before the controller can
be advanced onto cycle C5.
NOTE: Not all regeneration cycles may be used. A cycle will be skipped if it is not requred by the current program.
Cancelling a Regeneration
Action Key Duration Display
Cancel regen SET and UP 5 sec. Hourglass
starts to fl ash