PROBLEM CAUSE SOLUTION
16.Control will not regen- A. If water fl ow display is not operative, refer A. Same as Problem 10.
erate automatically but to Problem 10.
will regenerate when B. Defective circuit board. B. Replace timer.
button is pushed. C. Incorrect hardness and capacity settings. C. Set to correct values.
17.Run out of soft water A. Improper regeneration. A. Repeat regeneration, making certain that
between regenerations correct salt dosage is used.
B. Incorrect salt settings. B. Set control to proper level. See
Specifi cations.
C. Incorrect hardness. C. Set to correct values.
D. Water hardness has increased. D. Set hardness to new value.
E. Restricted meter turbine rotation due to E. Remove water housing, free up turbine
foreign material in meter. and fl ush with clean water. Turbine
should spin freely; if not, replace meter.