Operating instructions
To clean the refi ll fl ow control:
1) Place unit in bypass. Relieve water pressure by pushing open one of the last two valve discs.
2) Remove cap.
3) Pull refi ll fl ow control parts out.
4) Inspect parts for damage.
5) Flush with water and clean with soft brush.
6) Replace refi ll fl ow control parts.
7) Replace cap (hand tight).
DRAIN FLOW CONTROL
If the unit is not supplying conditioned water for as long as when it was fi rst setup, then the drain fl ow control
should be cleaned.
To clean the drain fl ow control:
1) Place unit in bypass. Relieve water pressure by pushing open one of the last two valve discs.
2) Remove the drain fl ow control and ball.
3) Inspect parts for damage.
4) Flush with water and clean with soft brush.
5) Orifi ce should be open not plugged.
6) Replace ball and drain fl ow control (hand tight).