Operating instructions

3-5
History Data
Description Range
H0 Resin volume initial setting value cubic feet
H1 Days since last regeneration 0-255
H2 Current fl ow rate 0-47 gpm
H3 Water used today in gallons since Time of Regeneration 0-65536 gallons
H4 Water used since last regeneration in gallons 0-65536 gallons
H5 Total water used since reset in 100s 0-65536 gallons
H6 Total water used since reset in 1,000,000 0-65536 gallons
H7 Average usage for Sunday in gallons 0-65536 gallons
H8 Average usage for Monday in gallons 0-65536 gallons
H9 Average usage for Tuesday in gallons 0-65536 gallons
H10 Average usage for Wednesday in gallons 0-65536 gallons
H11 Average usage for Thursday in gallons 0-65536 gallons
H12 Average usage for Friday in gallons 0-65536 gallons
H13 Average usage for Saturday in gallons 0-65536 gallons
When in history values mode a small “H” will be displayed in the lower left corner of the display. Next to the “H”
will be the number that applies to the history value.
H0 — System Resin Volume Setting
The history value H0 displays the initial resin volume setting (programmed when the system was fi rst set up). If
the value is incorrect and needs to be reset, press and hold the SET button for fi ve seconds to reset the controller.
CAUTION: Resetting the resin volume resets the entire controller back to the factory default. Only use
if absolutely necessary. The control will need to be completely reprogrammed.