User manual
• Problem: Displayed weight is inaccurate
• Solution: Perform a calibration adjustment
XI. Error Codes
1. OUTZ - Zero setting has shifted. Perform calibration
adjustment. If the problem persists, the load cell may
be permanently damaged due to overloading.
2. EEEEE - Maximum capacity exceeded. Remove the
extra weight to avoid damaging the load cell.
3. LLLLL - Load cell has been overloaded.
4. UNST - The scale is unstable. Use the scale in a
more stable position
XII. Specications
SR-1KG
Max. Capacity 1000g / 35.30oz
Readability 1g / 0.05oz
Min. Capacity 3g / 0.10oz
Power 2 x AAA Alkaline Batteries
Dimensions 4.0 x 2.3 x 0.7
Hook Dimensions Gap: 0.5in / Throat: 0.5in
Warranty 10 Year Limited Warranty
SR-5 SR-20
Max. Capacity 5kg / 11lb 20kg / 44lb
Readability 0.005kg / 0.01lb 0.01kg / 0.02lb
Min. Capacity 0.015kg / 0.03lb 0.03kg / 0.06lb
Power 2 x AAA Alkaline Batteries
Dimensions 4.0 x 2.3 x 0.7
Hook Dimensions Gap: 0.5in / Throat: 0.5in
Warranty 10 Year Limited Warranty