Specifications
Actassi Fibre
FL-C Fibre optic cables
Range Loose tube
OM2 50/125 µm
Type Length Diameter Ref. No
Optic cable Indoor/outdoor OM2 50/125 µm multimode bres, green overall jacket.
4 bres OM2 50/125, Loose tube,
Up to 10Gbps ethernet supported
2100 m 6,2mm VDIC52204L
6 bres, OM2 50/125, Loose tube,
Up to 10Gbps ethernet supported
525 m
2100 m
6,2mm VDIC42206L
VDIC52206L
8 bres, OM2 50/125, Loose tube,
Up to 10Gbps ethernet supported
2100 m 6,2mm VDIC52208L
12 bres, OM2 50/125, Loose tube,
Up to 10Gbps ethernet supported
525 m
2100 m
6,2mm VDIC42212L
VDIC52212L
24 bres, OM2 50/125, Loose tube,
Up to 10Gbps ethernet supported
525 m
2100 m
6,2mm VDIC42224L
VDIC52224L
Note: OM1 62,5/125 bre cable available on request for legacy installation, already using 0M1
bre core. Support up to 1Gbps ethernet
FL-C Loose tube Fibre optic cables
Specications
■ Compact and universal cables suitable for indoor and specic outdoor
installations:
– Low Smoke Zero Halogen (LSZH) green coloured external sheath
– UV resistant
– dielectric
– high tensile strength
– rodent retardant
– longitudinally watertight
■ Maximum pulling force: 1500 Newton (1800 Newton for 24FO)
– longitudinally watertight
■ Rodent protection:
■ Minimum bending radius: OD x 10 (ex: 62mm for 6,2mm OD)
■ Ambiant air temperature (minimum & maximum)
– for installation: -5° … +50°C
– for operation: -20°… +70°
– for storage: -40° … +70°
■ Loose tube gel-lled cable construction with 250 µm coating available in unitube
structure for 4, 6, 8 and 12 bres and bitube structure for 24 bres.
■ Flame retardant according to IEC 60 332-1, EN 50 265 2.1, NFC 32 070 2.1
(Category C2)
Performances
■ OM2 50/125 compliant with ITU G.651, IEC 60793-2-10 Type A1a.1 and
ISO/IEC 11801:2011 Ed2.2 OM2.
■ OM3 50/125 compliant with ITU G.651, IEC 60793-2-10 Type A1a.2 and
ISO/IEC 11801:2011 Ed2.2 OM3.
■ OM4 50/125 compliant with IEC 60793-2-10 Type A1a.3,
ISO/IEC 11801:2011 Ed2.2 OM4.
■ OS1/OS2 9/125 compliant with ITU G.652.D, IEC 60793-2-50 Type B1.3,
ISO/IEC 11801:2011 Ed2.2 OS2.
■ Cable mechanical characteristics tested according to IEC 60794-1
Use
■ High data rate bre optic backbones for building and campus
■ Suitable for splicing termination: installation with pigtails by fusion or mechanical
splices.
VDIC52204L
VDIC52206L
VDIC52212L
VDIC52224L
VDIC52224L
66 | Actassi 04.2012 | Network Connectivity