Specifications
Network Connectivity | 04.2012 Actassi | 47
Actassi CL-MNC F
2
cables
The efficient, reliable, invisible hero in
your office
Structured cabling is the vital link between all the components in your computer net-
work. Poor installation can cause severe bending and stress of cabling, often resulting
in system failure. Our “Tough” cabling incorporates a patent-pending F2 construction
that guarantees performance under widely varied installation quality. 4-twisted pairs of
high-purity solid copper wires optimize exibility, ease of installation and long-range
data transmission efciency. Durable PVC protective jacket ensures longer product life
by keeping cables tangle-free and enhancing tearresistance. High-density Polyethylene
insulation provides better protection and optimum resistance to extreme temperatures
and climactic conditions.
Superior headroom
and bandwidth.
CL-MNC F
2
Cat 6 UTP Cable Transmission
Performance Table
Freq
(MHz)
NEXT
(dB)
PS NEXT
(dB)
EL FEXT
(dB)
Attenuation
(dB/100m)
RL
(dB)
1.00 74.30 99.01 72.30 95.02 67.80 90.75 2.02 1.63 20.00 28.82
4.00 65.27 88.22 63.27 86.97 55.76 81.02 3.78 3.37 23.01 34.37
10.00 59.30 80.18 57.30 77.80 47.80 74.32 5.95 5.41 25.00 36.30
16.00 56.24 83.57 54.24 73.94 43.72 75.87 7.55 6.88 25.00 34.81
20.00 54.78 72.49 52.78 72.02 41.78 84.65 8.47 7.71 25.00 38.85
31.25 51.88 73.94 49.88 73.38 37.90 71.38 10.67 9.69 23.64 40.30
62.50 47.36 68.33 45.36 65.40 31.88 61.96 15.38 13.84 21.54 35.15
100.00 44.30 66.38 42.30 64.34 27.80 60.16 19.80 17.65 20.11 39.92
200.00 39.78 68.63 37.78 65.18 21.78 58.57 28.98 25.34 18.00 38.49
250.00 38.33 66.64 36.33 65.15 19.84 59.24 32.85 28.49 17.32 32.92
* Values in Grey refer to the requirement of TIA/EIA & ISO/IEC Standards
* Values in Green refer to Typical Actassi F
2
Cat6 UTP cable performance, tested based on 105
meters.