Technical data

8.13.17 SSI Encoder (X5, X1)
Wiring of a synchronous serial absolute encoder as a feedback system (primary or
secondary, ð p.62). The signal sequence can be read in Gray code or in Binary (stan
-
dard) code.
The thermal control in the motor is connected to X1 and evaluated there.
If cable lengths of more than 50m are planned, please consult our customer service.
Frequency limit: 1.5 MHz
Type FBTYPE EXTPOS GEARMODE
SSI 9 5 5
S300 Instructions Manual 79
Kollmorgen 09/2011 Electrical installation
S300