Technical data
8.13.12 ROD (AquadB) 5V with Hall (X1)
Wiring of a ComCoder as a feedback unit (primary, ð p.62). For the commutation hall
sensors are used and for the resolution an incremental encoder. The thermal control in
the motor is connected to X1 and evaluated there. With our ComCoder cable all signals
are connected correctly.With separate feedback devices (Encoder and Hall are two
devices) the wiring must be done similar to chapter 8.13.9, but the amplifier's pinout is
identical to the wiring diagram shown below.
If cable lengths of more than 25m are planned, please consult our customer service.
Frequency limit (A,B): 350 kHz
Type FBTYPE EXTPOS GEARMODE
AquadB 5V with Hall 15 - -
The pin assignment shown on the encoder side relates to the Kollmorgen motors.
74 S300 Instructions Manual
Electrical installation 09/2011 Kollmorgen
S300
SubD15
round, 17 pin