4.5 Disassembling
Observe the sequence below, if a servo amplifier has to be disassembled (e.g. for repla
-
cement).
1. Electrical disconnection
Switch off the main switch of the switchgear cabinet and the fuses that supply the
system.
Wait at least five minutes after disconnecting the servo amplifier from the main
supply power before touching potentially live sections of the equipment (e.g.
contacts) or undoing any connections. To be sure, measure the voltage in the DC
Bus link and wait until it has fallen below 40V.
Remove the connectors. Disconnect the earth (ground) connection at last.
2. Check temperature
During operation the heat sink of the servo amplifier may reach temperatures
above 80°C (176°F). Before touching the device, check the temperature and wait
until it has cooled down below 40°C (104°F).
3. Disassembling
Disassemble the servo amplifier (reverse of the procedure described in chapter "Mecha-
nical installation).
4.6 Repair
Repair of the servo amplifier must be done by the manufacturer. Opening the devices
means loss of the guarantee. Use the telefax form on page 130 for repair request. You'll
receive the current dispatch information.
Disassemble the equipment as described in chapter 4.5 and send it in the original packa-
ging to the address given in the dispatch information.
4.7 Disposal
In accordance to the WEEE-2002/96/EC-Guidelines we take old devices and accessories
back for professional disposal. Transport costs are the responsibility of the sender. Use
the telefax form on page 130 for disposal request. You'll receive the current dispatch
information.
Disassemble the equipment as described in chapter 4.5 and send it in the original packa-
ging to the address given in the dispatch information.
18 S300 Instructions Manual
Handling 09/2011 Kollmorgen