Technical data
4 Handling
4.1 Transport
l
Transport by qualified personnel in the manufacturer’s original recyclable packaging
l
Avoid shocks while transporting
l
Transport temperature: -25 to +70°C, max. rate of change 20K / hour,
class 2K3 acc. to EN61800-2
l
Transport humidity: max. 95% relative humidity, no condensation,
class 2K3 acc. to EN61800-2
l
The servo amplifiers contain electrostatically sensitive components, that can
be damaged by incorrect handling. Discharge yourself before touching the ser-
vo amplifier. Avoid contact with highly insulating materials, such as artificial
fabrics and plastic films. Place the servo amplifier on a conductive surface.
l
If the packaging is damaged, check the unit for visible damage. In such an event, in-
form the shipper and the manufacturer.
4.2 Packaging
l
Recyclable cardboard with inserts
l
Dimensions: (HxWxD) 115x365x275mm
l
Labeling: instrument label on outside of box
4.3 Storage
l
Storage only in the manufacturer’s original recyclable packaging
l
Max. stacking height 8 cartons
l
Storage temperature -25 to +55°C, max. rate of change 20K / hour,
class 1K4 acc. to EN61800-2
l
Storage humidity 5 ... 95% relative humidity, no condensation,
class 1K3 acc. to EN61800-2
l
Storage duration:
Less than 1 year: without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the
servo amplifier. To do this, remove all electrical connections and apply single-phase
230V AC for about 30 minutes to the terminals L1 / L2.
4.4 Maintenance, Cleaning
The instruments do not require any maintenance, opening the instruments invalidates the
warranty.
Cleaning : — if the casing is dirty: clean with Isopropanol or similar
NOTICE: do not immerse or spray
— Dirt inside the unit: must be cleaned by the manufacturer
— For dirty protective grill on fan: clean with a dry brush
S300 Instructions Manual 17
Kollmorgen 09/2011 Handling