Technical data

9.3.4 Setup Wizard
The Setup Wizard leads you through the necessary steps for configuring your servo
amplifier. Depending on the selected application, only the active screen pages are
necessary.
For a quick setup / drive
test, select the setup
type "Quick Motor/Drive
Setup".
Start the Wizard.
9.3.4.1 Basic Setup
Basic parameters are
setup here.
Response to Loss of Input Phase: Select Single-Phase or Three-Phase operation.
With three-phase operation you can select either warning "n05" or error "F19" in case of
phase loss. The reaction "F19" disables the output stage, "n05" is just a message.
Name: You can enter a name for the servo amplifier (up to 8 characters). This simplifies
the drive identification in the system.
Set Software Enable on Bootup: Don't select this option for the quick test.
Click NEXT.
100 S300 Instructions Manual
Setup 09/2011 Kollmorgen