User manual
Pleasemakevideocable,powercable,controlcable
andalarmcablepenetratedthebracket,andfixed
thebracketstably.Keepenoughlengthofcables:
Videocableshouldbekept50mmoutofthebracket,
andothercablesshouldbekept80-100mmfromthe
bracket.
Lock4piecesofM8screwandfixthebracketonthewall,
thensmeartheglasspasternonthejointsidebetween
wallandthebracketpadwhichpassedthelineinorder
topreventthewaterentering.(Refertobelowpicture)
Picture11.8-6
Glasspastern
:
AQUA:NC2
BROWN:NO2
GRAY:ALM7
PURPLE:ALM6
ORANGE:ALM5
Alarmterminal2
Alarmterminal1
:
RED:ALM1
PINK:ALM2
YELLOW:ALM3
GREEN:ALM4
BLACK:COM
WHITE:NO
BLUE:NC
RS485terminal:
YELLOW:RS485-
GREEN:RS485+
Powersupplyterminal
:
RED:AC24V+
YELLOW:GROUNDING
BLACK:AC24V-
Picture11.9-1
11.9CablingConnection
Pleaseconnectcablesrefertotheattachedtag.Detail
connectionrefertobelowlist.
11.10Electrificationinspection
Connectvideocableandcontrolcabletotheother
equipments;Electrify24VACpower.
ThePTZcarriesonself-checkingandexecutes
replacementprocedureafterpower-on.
Intheprocessofself-checking,camerawillrotate
horizontallyandslowlyforoneandhalfcycletothe
defaultoriginalhorizontalpointwhichissetbyfactory,
thenupwardlyturntooriginalverticalpoint,then
downwardlytooriginalhorizontalpoint.Lenswillbe
pulledfromfarfocustonearfocustocompleteself-
checking.Thewholecameraisabsolutelysteadymeans
PTZcompletedself-checkingandreadytobecontrolled.
Ifunstable,pleaserefertothetroubleshootinginthe
operationmanualappendix.
Picture11.8-5
01Cabling
02Inflationscrew
03Bracket
1
2
3
4
5
1.Alarmterminal2
2.Videoconnector
3.Alarmterminal1
4.RS485terminal
5.Powersupplyterminal
Yellow
Black
Red
ConnectiondrawingofInfraredLED
Picture11.9-2
Accordingtodifferentnight-visionfunction,youcanrefer
tothefollowingconnectiondrawing:
1.Alarmterminal2
2.Videoconnector
3.Alarmterminal1
4.RS485terminal
5.Powersupplyterminal
6.Searchlightpowersupply
RedAC24V+“”
BlackAC24V-“”
Red
Yellow
Black
5
6
1
2
3
4
NOTE:5and6shouldconnectwithaAC24Vadaptorindividually.
ConnectiondrawingofSearchlight
51
InstallationIntroduction