Technical data

PAGE 90
Operation via Windows PC Software
Display Contrast DAC: The communication with the display contrast
DAC is faulty.
VCXO: The communication with the voltage-controlled oscillator is
faulty.
•Under Application alarms you will find all potential application alarms.
A red LED signalises a currently existing alarm. The error counter shows
how often the alarm occurred after the unit has been connected to power.
AES3 Framing Input 1/2: If one of the digital Audio inputs has been
selected in the configuration dialogue, but no digital Audio signal is
available at the AES/EBU interface 1 or 2, the AES3 Framing Input 1 or
2 alarm will be set.
Ethernet Mode Supported: The Ethernet Mode alarm will be set if
your ethernet mode is not supported by the system. This is the case for
a 10 Mbit/s half duplex connection. Our recommendation is 100
Mbit/s full duplex.
AES3 External Clock: Currently not applicable.
The actual system temperature is displayed in °C under System Temper-
ature.
Ethernet status shows information about your ethernet connection.
•Under Abs. data rates the absolute data rates of your ethernet connec-
tions are displayed. TX stands for transmit direction and RX for receive di-
rection.
•Under Ethernet physical flags the following ethernet flags are displayed:
Extended
Auto
Negot.
Jabber
Remote Fault
All details concerning the LAN and IP settings are displayed under IP de-
tails.
IP Address
Sub Net Mask
Default Gateway
DNS Server
DHCP state
STUN state
The IP address of the Control PC connected to the system is shown under
Connected PCs.
TIP
A system alarm can also be configured as relay output (see Page 55).