Technical data
PAGE 94 
MAGIC TOUCH Software
After pressing the OK button the new password is accepted.
The key Cancel deletes the changes.
7.7.3.12.2 TCP/IP Access Protection
The access to the Telephone Hybrid system is defined in TCP/IP Access Pro-
tection. Only PCs with a registered IP address have access to the system.
To add an IP address press the Add button, to change an entry click the key
Edit and to delete an entry press Delete.
After pressing the Add or the Edit buttons, the window for entering the access
information opens. Enter in Name, an useful name for an easier identification
of the PCs.
FIG. 64 ENTRY OF A TCP/IP ADDRESS
Enter in TCP/IP Address the IP address of the PCs. 
Under Access Right activate the access right with yes. To withdraw the access
right of a PC - without deleting the entry - set this function to no.
After pressing the OK button all settings are accepted.
The key Cancel deletes all settings.
,
Please keep your own password in mind. The password protection can only
be cancelled by personnel expert of the company AVT.
L
All PCs which want to have access to the Hybrid system via the software op-
tions MAGIC TOUCH LAN or MAGIC SCREENER must be entered. This
also applies if MAGIC TOUCH,  MAGIC TOUCH LAN and MAGIC
SCREENER are to be used on one PC in parallel. In this case, enter the PC’s
own IP address.
For the MAGIC TOUCH LAN software, a so called Floating Licence is as-
signed, that means only as much PCs with MAGIC TOUCH LAN software
have access to the system in parallel as LAN licences (see CHAPTER 7.8.1,
page 110) are released.
In principle with the MAGIC SCREENER data base software an unlimited
number of PCs can have access to the Telephone Hybrid system simulta-
neously, since the licence is released as Multi User Licence. Please note that
the performance of the MS
®
 Access data base with DAO
1
 access decreases if
there are more than 5 users. 
1
DAO = Data Access Objects, Data access method of the Jet-Engine of MS
®
 Access
L
This name will be displayed in the list of the active TCP/IP connections in
Administration 
→ 
List
TCP/IP Connections (see CHAPTER 7.8.3, page 113)
as soon as the PC access the Hybrid system.