User Manual
Table Of Contents
- Introduction
- Features
- In The Box
- Specifications
- The Transmitter
- Indicator Troubleshooting Lights - Transmitter
- Functions & Setup of the Transmitter
- Settings Button - Transmitter without Dip Switches
- Test Pattern Button - Transmitter with Dip Switches
- The Receiver
- Indicator Troubleshooting Lights - Receiver
- Settings Button - Receiver
- IR Configuration
- Extracted Audio - L/R OUT
- Audio Extraction Example
- RS-232 Pass-through
- Troubleshooting
- Bandwidth Chart
- Maintenance
- Damage Requiring Service
- Support
- Warranty
7
EDID Management: GEN2 (pre DIP Switches)
Press the SETTINGS button to cycle through the EDIDs
4 LED lights on the board inside the chassis (see below)
·Solid LED = ON
·Flashing LED = OFF
Copy EDID: To COPY EDID from Sink Device, press the settings button until only LED #4 is lit up
(USER EDID). With the Sync Device powered on and the USER EDID Slot selected, press and hold
the settings button for approximately 5 seconds to copy and save that EDID. The red POWER LED will
ash conrming copy successful.
NOTE: If you press and hold the SETTINGS button in any other state besides USER EDID,
this will enable/disable the 4K to 2K Down-Scaler�
EDID Management:GEN2 (NEW FOR 2022) with DIP
Switches on the bottom of the Transmitter
The rst 3 are used to set the EDID
·OFF/UP/0
·ON/DOWN/1
Examle set to
EDID BYPASS
(Default)