User Manual

In the example below a control system is plugged into the “IR IN” port of the
HDBaseT Transmitter with a 3.5mm mono cable. The IR MODE Switch is set to I-PASS
and a IR Emitter is plugged into the “IR OUT” port of the HDBaseT Receiver. This
allows you to send an IR signal from a control system down the category cable to the
sink (RX) and control the display.
IPASS - This port is designed to be directly connected
to a control system via a 3.5mm Mono cable
NOTE: IPASS is only an INPUT� So you can go IPASS in
from a control system to IR OUT�
Control System > IPASS (TX) ------IR OUT (RX)
Control System > IPASS (RX) ------IR OUT (TX)
See example below
12