User Manual

Functions & Setup
of the Transmitter:
IR Mode Slide Switch: (On Front) This is used to select a preferred IR Mode - There are two modes:
IR-EYE - The IR Input will be configured to operate with an IR Receiver Eye.
I-PASS - The IR Input will be configured to safely operate with a direct connection from a control
system using a mono or stereo 3.5mm cable. It's protected @ 3v-20v. Default mode is IR-EYE.
EDID Management:
Dip Switch Located
on side of Transmitter
UP = 0 = Off
Down = 1 = On
COPY EDID Function:
Set DIP Switches 1, 2, and 3 to the DOWN position (ON)
While everything is powered up, set DIP Switch 5 to the DOWN position (ON). Wait a moment, then Set DIP Switch
5 back UP (OFF) to disable the TEST PATTERN. This will copy the EDID to the USER EDID memory with HDBaseT in
Priority. This means the that it will copy from the display plugged into the Receiver.
Why do this?
This is commonly used when there is a need for a specific, known EDID that the installer may prefer. It can also be used if
you want to bypass an EDID of an AVR or another connected device. (IE, plug the extender kit directly into a display and
COPY the EDID. Plug it back into an AVR that may not have a current/good EDID).
SCALER SETTINGS:
DIP Switch 4, UP (OFF) - The scaler is OFF
DIP Switch 4, DOWN (ON) the incoming 4k signal will be downscaled to 1080P
TEST PATTERN:
DIP Switch 5, UP (OFF/DISABLED) - The test pattern is off
DIP Switch 5, DOWN (ON/ENABLED) - A 1080p test pattern is generated
AC-EX40-444-PLUS