Operator`s manual
Page 168 – 9. Cue Lists
TitanUniversal_Man_v7-0_PE.doc 02 September 2013
between the previous cue firing and this cue firing, set either in
seconds or as a percentage of the fade time of the previous
cue.
These options allow you to create complex self timed sequences by
building up simple steps. For example if you wanted the following
effect:
• Go is pressed, fixture one starts fading up over 20s
• After 10s fixture two fades up over 15s
• Both lights stay on for 5s
• Both lights go off in 3s
You could program
• Cue 1 - Fixture 1 @ 100%, Fade In 20s, Link Wait For Go
• Cue 2 - Fixture 2 @ 100%, Fade In 15s, Link With Previous,
Link Offset 10s
• Cue 3 - Fixture 1 AND 2 @ 0%, Fade Out 3s, Link After
Previous, Link Offset 5s
To obtain the effect which was called “cue overlap” in
previous versions of software, use [Link With Previous
Cue] and set a percentage Link Offset time. Link Offset
of 100% is equivalent to Cue Overlap of 0% and vice
versa.
9.5.3 Individual attribute fade times
You can set individual fade times for each IPCGBES attribute group.
You can also select which fixtures this is applied to. For example you
can make the position change take 2 seconds, but the colour change
take 10 seconds.
Additionally you can set individual times for each attribute so you
could make the pan fade over a different time to the tilt.