Operator`s manual

Copyright Avolites Limited 2010
Page 40 – 2. Patching
PearlExpertTitan_Man_v4.doc 29/09/2010 16:27:00
4> The LCD will show what you are deleting. Press the Select
button again to confirm.
All programming for the fixture is also deleted. You cannot undo
deletion of a fixture or get the programming back by repatching
a fixture to the same handle.
2.5 Advanced options
2.5.1 Swap pan and tilt
This allows you to make the pan channel control tilt and the tilt
control pan. This is useful for moving-mirror fixtures rigged sideways.
1> Press Patch.
2> Press [Edit Fixtures]
3> Press [Swap Pan and Tilt].
4> Select the fixtures to be pan-tilt swapped. Press [Pan and Tilt
…] to select either [Swapped] or [Normal] for the selected
fixtures.
5> Press Exit when finished.
2.5.2 Invert attributes
This option inverts individual attributes of fixtures. Useful if you have
a fixture which pans right when the rest pan left, saving a trip up the
rig to set fixture options, but you can invert any attribute.
1> Press Patch.
2> Press [Edit Fixtures].
3> Press [Invert Attribute]
4> Select fixture(s) to be changed.
5> Select the attribute to invert from the softkeys. The display
shows [Inverted] when the attribute is inverted.
6> Press Exit to finish.
You can change the invert on multiple fixtures by selecting
more than one, but the “Inverted” display will not show if there
is a mixture of inverted and non-inverted fixtures in the
selection.
Some attributes cannot be inverted.
2.5.3 Freeze fixtures or attributes
This option allows you to freeze individual attributes of a fixture, or to
freeze the whole fixture. Attributes or fixtures which are frozen are
not affected by playbacks or by the programmer.
1> Press Patch.
2> Press [Edit Fixtures]
3> Press [Freeze Fixture or Attribute].
4> Select the fixtures to be frozen/unfrozen.