DSRIQ-SRL module pinouts
Table B.1 lists the pinouts for the DSRIQ-SRL module.
DB9-F Pin Host Signal Name Description Signal Flow SRL Signal Name Description
1 DCD - Data Carrier Detect Out of SRL DTR - Data Terminal Ready
2 RXD - Receive Data Out of SRL TXD - Transmit Data
3 TXD - Transmit Data In to SRL RXD - Receive Data
4 DTR - Data Terminal Ready In to SRL DSR - Data Set Ready
5 GND - Signal Ground N/A GND - Signal Ground
6 DSR - Data Set Ready Out of SRL DTR - Data Terminal Ready
7 RTS - Request to Send In to SRL CTS - Clear to Send
8 CTS - Clear to Send Out of SRL RTS - Request to Send
9 N/C - Not Connected N/A N/C - Not Connected
Table B.1: DSRIQ-SRL Module Pinouts
Using MPUIQ-SRL Modules
An administrator can choose between the ACS console server and Cisco® pinouts for each MPUIQ-SRL serial
port via the local user interface or the remote OBWI. ACS is the default.
To change the pinout to Cisco mode:
1. Select Unit View - Appliance - Appliance Settings - Ports - RIPs.
2. Click on the desired RIP.
3. Select Settings - Pinout.
NOTE: If the DB9 adaptor is used, select the ACS console server pinouts.
ACS console server port pinouts
The following table lists the ACSconsole server serial port pinouts for the MPUIQ-SRL module.
Pin No. Signal Name Input/Output
1 RTS - Request to Send OUT
2 DTR - Data Terminal Ready OUT
3 TXD - Transmit Data OUT
4 GND - Signal Ground N/A
5 CTS - Clear to Send IN
6 RXD - Receive Data IN
Table B.2: ACS Console Server Serial Port Pinouts
Appendices 57