218 DSView Installer/User Guide
device td-john, while 520255-03F757 is connected to td-mary and 520255-016BE0 is connected
to td-tim.
Example: Cascade switch connection
dsr-1021-huntsville(1)
→520255-023FB7→switch one (1)→520255-023FB701
dsr-1021-huntsville(1)
→520255-023FB7→switch one (2)→520255-023FB702
dsr-1021-huntsville(1)
→520255-023FB7→switch one (3)→520255-023FB703
dsr-1021-huntsville(1)
→520255-023FB7→switch one (4)→520255-023FB704
dsr-1021-huntsville(1)
→520255-023FB7→switch one (5)→520255-023FB705
dsr-1021-huntsville(1)
→520255-023FB7→switch one (6)→520255-023FB706
dsr-1021-huntsville(1)
→520255-023FB7→switch one (7)→520255-023FB707
dsr-1021-huntsville(1)
→520255-023FB7→switch one (8)→520255-023FB708
In the above example, an Autoview 200 1 x 8 switch is connected to port one of a DSR1021 switch
named dsr-1021-huntsville using a DSRIQ module with an EID of 520255-023FB7. Each port of
the AutoView 200 switch is connected to a different target device
(520255-023FB701-520255-023FB708).
Example: SPC device connection
dsr-1021-huntsville(SPC)
→02-17-F2 SPC (A1)→02-17-F2 SPC A1
In the above example, an SPC switch is connected to the SPC port of a DSR1021 switch named
dsr-1021-huntsville. SPC device outlet A1 is connected to target device 02-17-F2 SPC A1.
Customizing the Target Device Connections window
By default, the following field displays the Target Device Connections window and may be
removed using the Customize link:
• Type - Displays the type of connection:
• KVM - A connection to a port of a DSR switch using a DSRIQ module.
• Serial - A serial port connection to a CPS appliance.
• Power - A connection to an SPC device outlet.
See Using the Customize Link in DSView Software Windows on page 15 for information on using